Required fire resistance
Leave blank for the code value; follow the design documents if they differ
Column bracing follows columns, floor bracing follows beams, roof bracing and ties follow roof members (GB 51249 cl. 3.1.1)
Code value: 2.50 h (GB 50016 Table 3.2.1)
Section and area
Heated perimeter ÷ area; enter it here if no section is picked
Coating and thickness
From the product type-test report for this rating; this governs on site (T/CECS 24-2020 cl. 3.1.6)
Code estimate (optional, for comparison)
Quantity and cost
From the datasheet; if only dry density is given, use density kg/m³ ÷ 1000 (indoor non-intumescent ≤ 500 kg/m³, GB 14907 Table 2)
Depends on method and member size; blank = 0
Optional, for pack count
Optional, labour per m²
The estimate uses GB 51249-2017 eq. (7.2.8): standard fire curve, lightweight protection, contour coating; for reference only. Minimum thicknesses follow GB 14907-2018 cl. 5.1.5. The applied thickness follows the product type-test report and the designer's approval. Ratings follow GB 50016-2014 (2018); the design documents govern if they differ.
Primer and intermediate coats: Paint estimator