Height and pitch
Fix the pitch by
Floor at the foot to the landing at the top
Common: 35.5°, 45°, 59°, 73°
Blank = auto, bringing g + 2r closest to 600
Common combinations (g + 2r = 600)
| Pitch angle | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Going g | 280 | 250 | 230 | 200 | 180 | 150 | 130 | 110 | 90 | 70 |
| Riser r | 160 | 175 | 185 | 200 | 210 | 225 | 235 | 245 | 255 | 265 |
Example values from GB 4053.2; tap to use the angle
Result
Enter the height and the pitch
- Steps = number of risers = number of treads: the top tread is flush with the landing.
- g + 2r shall be 550–700 mm; a flight shall not exceed 6 m, otherwise split it with a landing (GB 4053.2).
- Pitch: 30°–75° in GB 4053.2-2009, preferably 30°–35°, at most 38° for frequent two-way use and 42° for occasional use; the 2025 edition (in force from 2027-01-01) admits pitches above 20°.
- Slope length is the pitch line, not the stringer cutting length; add end details from the drawings. Fixed industrial steel stairs only, not ladders, spiral stairs or building staircases.
Sections and chequered plate for stringers and treads: Steel handbook